1. Attention

    Settings shown will vary depending upon the machine configuration.

    1. Select the Main Output button at the top of the screen.

      1. Franker (if fitted):
        • Franker settings: Dynamic franker options available are: Presorted or Letterbox (different types of frank); Message (preset string is printed) or Passthrough (franker not used); Letterbox or Presorted (different types of frank) or Dater (prints current date). Not used disables the franker.

        Vertical Stacker:

        • Jog mode: Set the action to trigger Jog mode. Jog moves filled envelopes to an offset position on the stacker conveyor, for identification purposes.
        • Error Handling: Select whether errors should cause the machine to stop with the error on the track at the shuttle, or at the output (ie, either on the conveyor/stacker or diverted to a divert unit (where fitted).
        • Brush offset: Adjusts the degree of contact of the brush with the envelope. This may be need, for example, if you are using thick packs.

        Envelope printer (if fitted):

        • Job name: The job name applies to the Flexmail project that the printer is using and which the software will use when running the machine. The scripting is the Flexmail language used in the project. Options are No printing / Sequential / Database lookup.
        • Scripting mode: This defines how the printer actions the mailpiece.
        • Pass through/No printing: Mailpieces continue unprinted to franker or conveyor.
        • Mail shot/Sequential: Mailpieces will be printed with data supplied by Flexmail database in a sequential order from top to bottom.
        • Matching/DB lookup: Mailpieces will be printed with data read from the column in the Flexmail database named under the Lookup option in the Edit Printer Settings dialog box. This is defined by the characters selected in the barcode.
          This allows selective data to be read from the database.
        • Mail shot/Sequential (non-reset): As Mail shot/Sequential but if machine is Autoended, then switched back on, it will continue where it left off in the database. Without non-reset, the machine will restart at the first entry.
        • Matching/Dynamic DB lookup: As Matching/DB lookup except the database is not located locally on the Flexmail PC, but accessed remotely via AIMS.
        • Mailshot/Dynamic Sequential: As Mail shot/Sequential except the database is not located locally on the Flexmail PC, but accessed remotely via AIMS.

        Lookup: The name of the column in the Flexmail database named under the Lookup option in the Edit Printer Settings dialog box. This is defined by the characters selected in the barcode.

        Weighing device (if fitted):

        • Weighing mode: Sets the operation of the Weighing Scale. Off (Pass through) disables the scale so documents pass through unweighed; On (Fixed) is for future development and should not be used; On (Dynamic) recieves calculated weight data from the inserter and compares it to the weighed data; if there is a disparity, an error will be flagged.

        Full Format Pack Divert (if fitted):

        • Tandem mode (FFPD units only): Off disables FFPD mode so unit operates as a diverter. FFPD (mix) directs some forms to FFI Inserter and some to the DS-1200 folder, according to barcode. FFPD (always) directs all forms to the FFI Inserter.
    2. Select the Diverts button at the top of the screen (if output diverts are fitted).

    3. Set the divert category for Envelope diverts 1, 2 & 3 and the criteria to trigger Jog 1 & 2 mode (where these are fitted).

    4. Press Next when finished.